Zeror.ai Error Codes Fanuc PS0200

Fanuc PS0200

Brand: FanucModel: FANUC 0i-FError code: PS0200

What the Fault Means

ILLEGAL S CODE

Likely causes

  • 1) In the rigid tapping, an S value was out of COMMAND range or was not specified. The parameter (Nos. 5241 to 5243) setting is an S value which can be specified for the rigid tapping. Correct the parameters or modify the program. 2) Rigid tapping is commanded during constant surface speed control.

Solution and Safe First Checks

  1. Refer to FANUC 0i-F operator manual

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Fanuc error codes

Source: the Zeror.ai industrial fault database and Fanuc technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Fanuc PS0200 · Zeror.ai