Zeror.ai Error Codes Fanuc PS0205

Fanuc PS0205

Brand: FanucModel: FANUC 0i-FError code: PS0205

What the Fault Means

RIGID MODE DI

Likely causes

  • Although a rigid M code (M29) is specified in rigid SIGNAL OFF tapping, the rigid mode DI signal (G061.0) is not ON during execution of the G84 (or G74) block. Check the PMC ladder diagram to find the reason why the DI signal is not turned on. 0206 CAN NOT CHANGE Plane changeover was instructed in t

Solution and Safe First Checks

  1. Refer to FANUC 0i-F operator manual

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.