Zeror.ai Error Codes KUKA ACKN MONITORING OF THE ACTUAL VELOCITY **

KUKA ACKN MONITORING OF THE ACTUAL VELOCITY **

Brand: KUKAModel: KRC SystemError code: ACKN MONITORING OF THE ACTUAL VELOCITY **

What the Fault Means

ACKN MONITORING OF THE ACTUAL VELOCITY **

Likely causes

  • - Fault in control loop:
  • - motor cables of two axes interchanged;
  • - error in the axis assignment;
  • - power module defective;
  • - resolver unmastered.

Solution and Safe First Checks

  1. - Rectify the corresponding error in the control loop.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related KUKA error codes

Source: the Zeror.ai industrial fault database and KUKA technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

KUKA ACKN MONITORING OF THE ACTUAL VELOCITY ** · Zeror.ai