Zeror.ai Error Codes KUKA KRC2-370

KUKA KRC2-370

Brand: KUKAModel: KRC2Error code: KRC2-370

What the Fault Means

Phase voltage missing DSE <DSE number> KPS <KPS number>

Likely causes

  • One phase of the voltage supplied by the KPS is missing. This may even
  • be upstream of the cabinet connection.
  • It is also possible that the corresponding cabinet wiring is missing.

Solution and Safe First Checks

  1. Check the power supply of all three phases. Check the required cabinet
  2. wiring: X110/pin 2 must be connected to 24 V and X110/pin 3 must be
  3. connected to GND.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related KUKA error codes

Source: the Zeror.ai industrial fault database and KUKA technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

KUKA KRC2-370 · Zeror.ai