Zeror.ai Error Codes Siemens F00006

Siemens F00006

Brand: SiemensModel: SINAMICS G120Error code: F00006

What the Fault Means

Fault: Chip temperature rise exceeds critical levels.

Likely causes

  • Load at start-up is too high
  • Load step is too high
  • Ramp-up rate is too fast

Solution and Safe First Checks

  1. Load or load step too high?
  2. Reduce ramp-up time (P1120).
  3. Motor power (p0307) must match inverter power (r0206).
  4. Use setting P0290 = 0 or 2 for preventing F00006.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens F00006 · Zeror.ai