Zeror.ai Error Codes Siemens F01356

Siemens F01356

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F01356

What the Fault Means

Fault: Topology: There is a defective DRIVE-CLiQ component

Likely causes

  • The actual topology indicates at least one defective DRIVE-CLiQ component
  • Fault value (r0949, interpret hexadecimal): zzyyxx hex: zz = connection number of the component at which the defective component is connected yy = component number of the component at which the defective component is connected xx = fault cause xx = 1: Component at this Control Unit not permissible
  • xx = 2: component with communication defect
  • Note: Pulse enable is withdrawn and prevented.

Solution and Safe First Checks

  1. Replace the defective component and restart the system.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.

Siemens F01356 · Zeror.ai