Zeror.ai Error Codes Siemens F01375

Siemens F01375

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F01375

What the Fault Means

Fault: Topology: Connection duplicated between two components

Likely causes

  • When checking the actual topology, a ring-type connection was detected
  • The fault value describes a component contained in the ring
  • Fault value (r0949, interpret hexadecimal): ccbbaaaa hex: cc = connection number (%3) bb = component class (% 2) aaaa = preliminary component number (%1) Component class: 0: Component unknown
  • 1: Control Unit 2: Motor Module 3: Line Module 4: Sensor Module 5: Voltage Sensing Module 6: Terminal Module 7: DRIVE-CLiQ Hub Module 8: Controller Extension 9: Filter Module 10: Hydraulic Module

Solution and Safe First Checks

  1. Output the fault value and remove the specified connection.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.