What the Fault Means

Fault: Drive: DC link voltage monitoring Vdc_max

Likely causes

  • The monitoring of the DC link voltage p1284 has responded (only U/f control).

Solution and Safe First Checks

  1. check the line supply voltage.
  2. check the braking module.
  3. adapt the device supply voltage (p0210).
  4. adapt the DC link voltage monitoring (p1284).

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.