Zeror.ai Hata Kodları Siemens F07985

Siemens F07985

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: F07985

Hatanın Anlamı

Fault: Drive: Speed controller optimization (oscillation test)

Olası nedenler

  • A fault has occurred during the vibration test
  • Fault value (r0949, interpret decimal): 1: The speed did not reach a steady-state condition
  • 2: The speed setpoint was not able to be approached as the minimum limiting is active
  • 3: The speed setpoint was not able to be approached as the suppression (skip) bandwidth is active

Çözüm ve Güvenli İlk Kontroller

  1. check the motor parameters (rating plate data). After the change: Calculate p0340 = 3.
  2. check the moment of inertia (p0341, p0342). After the change: Calculate p0340 = 3.
  3. carry out a motor data identification routine (p1910).
  4. if required, reduce the dynamic factor (p1967 < 25 %).
  5. adapt the speed setpoint (p1965) or adapt the minimum limit (p1080).
  6. adapt the speed setpoint (p1965) or suppression (skip) bandwidths (p1091 ... p1094, p1101).

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.