Siemens F07984

Бренд: SiemensМодель: SINAMICS G120 CU250S2Код ошибки: F07984

Что означает ошибка

Fault: Drive: Speed controller optimization, moment of inertia

Вероятные причины

  • A fault has occurred while identifying the moment of inertia
  • Fault value (r0949, interpret decimal): 1: The speed did not reach a steady-state condition
  • 2: The speed setpoint was not able to be approached as the minimum limiting is active
  • The speed setpoint was not able to be approached as the suppression (skip) bandwidth is active

Решение и первые безопасные проверки

  1. check the motor parameters (rating plate data). After the change: Calculate p0340 = 3.
  2. check the moment of inertia (p0341, p0342). After the change: Calculate p0340 = 3.
  3. carry out a motor data identification routine (p1910).
  4. if required, reduce the dynamic factor (p1967 < 25 %).
  5. adapt the speed setpoint (p1965) or adapt the minimum limit (p1080).
  6. adapt the speed setpoint (p1965) or suppression (skip) bandwidths (p1091 ... p1094, p1101).

Безопасность: не работайте внутри шкафа без снятия напряжения; при сомнениях обратитесь к квалифицированному специалисту.

Похожие коды ошибок Siemens

Источник: промышленная база неисправностей Zeror.ai и техническая документация Siemens. Страница носит информационный характер; на критичных системах следуйте руководству производителя и авторизованной службе.

Siemens F07984 · Zeror.ai