Siemens F30630

Бренд: SiemensМодель: SINAMICS G120 CU250S2Код ошибки: F30630

Что означает ошибка

Fault: SI P2: Brake control error

Вероятные причины

  • motor cable is not shielded correctly.
  • defect in the Safe Brake Module, in the Power Module or in the Control Unit.
  • parameter p1278 incorrectly set.
  • no brake connected or wire breakage (check whether brake releases for p1278 = 1 and p9602/p9802 = 0 (SBC deactivated)).
  • ground fault in brake cable.
  • no brake connected or wire breakage (check whether brake releases for p1278 = 1 and p9602/p9802 = 0 (SBC deactivated)).

Решение и первые безопасные проверки

  1. check parameter p1278 (for SBC, only p1278 = 0 is permissible).
  2. select Safe Torque Off and de-select again.
  3. check the motor holding brake connection.
  4. check the function of the motor holding brake.
  5. check the Safe Brake Module connection.
  6. check that the electrical cabinet design and cable routing are in compliance with EMC regulations (e.g. shield of the

Безопасность: не работайте внутри шкафа без снятия напряжения; при сомнениях обратитесь к квалифицированному специалисту.

Похожие коды ошибок Siemens

Источник: промышленная база неисправностей Zeror.ai и техническая документация Siemens. Страница носит информационный характер; на критичных системах следуйте руководству производителя и авторизованной службе.