Zeror.ai Error Codes Siemens F07460

Siemens F07460

Brand: SiemensModel: SINAMICS G120 CU250S2Error code: F07460

What the Fault Means

Fault: EPOS: End of reference cam not found

Likely causes

  • During the search for reference, when the axis reached the zero mark it also reached the end of the traversing range without detecting an edge at the binector input "reference cam" (BI: p2612)
  • Maximum traversing range: -2147483648 [LU] ..
  • -2147483647 [LU]

Solution and Safe First Checks

  1. check the "reference cam" binector input (BI: p2612).
  2. repeat the search for reference.

Safety: do not work inside the panel without isolating the power; if unsure, consult a qualified technician.

Related Siemens error codes

Source: the Zeror.ai industrial fault database and Siemens technical documentation. This page is for information; on critical systems follow the manufacturer's manual and authorised service.