Siemens F01034

Marca: SiemensModelo: SINAMICS G120 CU250S2Código de error: F01034

Qué Significa el Fallo

Fault: Units changeover: Calculation parameter values after reference value change

Causas probables

  • The change of a reference parameter meant that for an involved parameter the selected value was not able to be recalculated in the per unit representation
  • The change was rejected and the original parameter value restored
  • Fault value (r0949, parameter): Parameter whose value was not able to be re-calculated
  • See also: p0304, p0305, p0310, p0596, p2000, p2001, p2002, p2003, r2004

Solución y Primeras Comprobaciones Seguras

  1. Select the value of the reference parameter such that the parameter involved can be calculated in the per unit
  2. Technology unit selection (p0595) before changing the reference parameter p0596, set p0595 = 1.

Seguridad: no trabajes dentro del cuadro sin cortar la energía; si tienes dudas, consulta a un técnico cualificado.