Zeror.ai Hata Kodları Siemens F01034

Siemens F01034

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: F01034

Hatanın Anlamı

Fault: Units changeover: Calculation parameter values after reference value change

Olası nedenler

  • The change of a reference parameter meant that for an involved parameter the selected value was not able to be recalculated in the per unit representation
  • The change was rejected and the original parameter value restored
  • Fault value (r0949, parameter): Parameter whose value was not able to be re-calculated
  • See also: p0304, p0305, p0310, p0596, p2000, p2001, p2002, p2003, r2004

Çözüm ve Güvenli İlk Kontroller

  1. Select the value of the reference parameter such that the parameter involved can be calculated in the per unit
  2. Technology unit selection (p0595) before changing the reference parameter p0596, set p0595 = 1.

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.