Zeror.ai Hata Kodları Siemens F30659

Siemens F30659

Marka: SiemensModel: SINAMICS G120 CU250S2Hata kodu: F30659

Hatanın Anlamı

Fault: SI P2: Write request for parameter rejected

Olası nedenler

  • The write request for one or several Safety Integrated parameters on processor 2 was rejected
  • Note: This fault does not result in a safety stop response
  • Fault value (r0949, interpret decimal): 10: An attempt was made to enable the STO function although this cannot be supported
  • 15: An attempt was made to enable the motion monitoring functions integrated in the drive although these cannot be supported

Çözüm ve Güvenli İlk Kontroller

  1. check whether there are faults in the safety function alignment (F01655, F30655) and if required, carry out
  2. use a Control Unit that supports the required function.
  3. use the power unit with the feature "STO via terminals at the Power Module".

Güvenlik: Enerjiyi kesmeden pano içi işlem yapmayın; emin değilseniz yetkili teknisyene danışın.

İlgili Siemens hata kodları

Kaynak: Zeror.ai endüstriyel arıza veritabanı ve Siemens teknik dokümantasyonu. Bu sayfa bilgilendirme amaçlıdır; kritik sistemlerde üretici kılavuzunu ve yetkili servisi esas alın.