Siemens F30659

Бренд: SiemensМодель: SINAMICS G120 CU250S2Код ошибки: F30659

Что означает ошибка

Fault: SI P2: Write request for parameter rejected

Вероятные причины

  • The write request for one or several Safety Integrated parameters on processor 2 was rejected
  • Note: This fault does not result in a safety stop response
  • Fault value (r0949, interpret decimal): 10: An attempt was made to enable the STO function although this cannot be supported
  • 15: An attempt was made to enable the motion monitoring functions integrated in the drive although these cannot be supported

Решение и первые безопасные проверки

  1. check whether there are faults in the safety function alignment (F01655, F30655) and if required, carry out
  2. use a Control Unit that supports the required function.
  3. use the power unit with the feature "STO via terminals at the Power Module".

Безопасность: не работайте внутри шкафа без снятия напряжения; при сомнениях обратитесь к квалифицированному специалисту.

Похожие коды ошибок Siemens

Источник: промышленная база неисправностей Zeror.ai и техническая документация Siemens. Страница носит информационный характер; на критичных системах следуйте руководству производителя и авторизованной службе.